We guarantee the lowest price and will not be beat on our products such as portable dehumidifiers & whole house dehumidifiers, including brands like Santa Fe Dehumidifiers models!! Just pick up the phone, call us now. As an authorized dealer we declare to provide the best service, advice and pricing amongst other authorize dealers.

Call (800) 621-0871
Mon-Sun 10am-8pm EST

Live Chat by Chesapeake Air Purifiers

Live chat by Chesapeake Air Purifiers

Secured by VeriSign HACKER SAFE certified sites prevent over 99.9% of hacker crime.

IQAIR CLEANROOM SERIES

GUARANTEED 1-DAY DELIVERY (MUST CALL TO RESERVE!!)

For filtration of microorganisms and other particles. Specially designed for infection control units, TB isolation rooms, critical particle control, use in cleanrooms up to Class 100.

Call for current price!

(800) 621-0871


Specifications -IQAir Cleanroom Series Other Information


"FREE EXPEDITED SHIPPING !"


1. User Control Panel
2. Carrying Handle
3. No-Draft Diffuser
4. Cleanroom-Grade HyperHEPA Filter
5. Snap-Open Locking Arms
6. High-Performance Centrifugal Fan
7. Advanced Fan Control
8. Pre-Max Pre-Filter (Class F9)
9. Dual Floor Air Intake
General
Number of Selectable Fan Speeds 5
Air Delivery (with new filters installed) per Speed 1 - 45 cfm
2 - 70 cfm
3 - 90 cfm
4 - 155 cfm
5 - 270 cfm
Maximum Coverage Area 1200 sq ft (based on maximum fan speed and an 8.5 ft ceiling)
System Efficiency for Particles

99.99% or more at 0.3 microns
99.7% for smaller particles

Power Requirements 115 VAC 50-60 Hz   The entire electrical system is UL certified.
Energy Consumption (Max) 195 W
Standby Energy Consumption 2.5 W
Power Cable Detachable 6 foot
Dimensions H 32"     W 15"     D 16"
Net Weight (including filters) 33 lbs
Warranty Period 1 yr on unit including fan motor, excluding filters
Filters
Number of Filter Stages 2 (fine dust and micro dust filtration)
Total Number of Replacement Filters 2 (pre-filter, HEPA Filter)
Pre-Filter 32 sq ft mini-pleat fine dust filter
HEPA Filter Efficiency 99.97% at .3 microns
HEPA Filter Surface Area 44 sq ft.
Filter Frame Material Expanded polystyrene (EPS), chlorofluorocarbon (CFC) - free
Filter Life Pre-Filter 6-18 months
HEPA up to 2 years (filter life is dependant on the operating environment)
Professional Control Airborne Particulates

The IQAir® Cleanroom Series has been designed specifically for the removal of airborne particles. The systems feature the highest air delivery and longest filter life of any IQAir particle filter system. To allow for maximum air delivery the systems contain no gas phase filtration.

The Cleanroom Series provides a choice of 2 models, each with a specific filter efficiency and air delivery profile. While healthcare facilities may require higher air delivery to achieve optimum control of microorganisms (e.g. in ICUs or TB isolation rooms), a cleanroom facility may need a filtration efficiency of 99.97% to meet strict manufacturing regulations or standards.

Positive and Negative Pressure Environments

Each IQAir® Cleanroom system can be used as a recirculation device or it can be combined with IQAir's ducting adapters InFlow W125 or OutFlow W125 to create positive and negative pressure environments. The creation of negative pressure helps to contain harmful particles, such as microorganisms, in a particular area (e.g. TB isolation).

The creation of positive pressure helps to protect clean areas from contaminants entering from adjacent rooms (e.g. protective isolation of immuno-compromised patients, controlled environments for medical device manufacturing).

Decentralised Airborne Infection Control in Health-Care Facilities

Airborne pathogens in health-care environments pose a particular risk to immunocompromised patients who may inhale fungal spores, bacteria and viruses. Airborne microorganisms can not only complicate recovery from surgery, but can also lead to life-threatening infections,costing health-care services hundreds of millions every year.

Hospital-acquired aspergillosis for example has been recognised increasingly as a cause of severe illness and high mortality in immunocompromised individuals, e.g. patients undergoing chemotherapy and/or organ or bone marrow transplants. In the light of the marked increase in nosocomial infections over recent years, many of which are caused by drug-resistant pathogens, the importance of using high-efficiency air filtration systems beyond the confines of so-called “critical areas” (such as operation theatres) has once again been emphasised. Both the World Health Organisation (WHO) and the Centers for Disease Control and Prevention (CDC), advise that, wherever possible, preventive infection control measures should be implemented to reduce the risk of nosocomial infections.

 

Features of IQAir Cleanroom Air Purifiers


Remote Control


IQAir HEPA Filter

Housing
Number of Housing Modules 6
Housing Material PC-ABS and ABS(UV-stabilized)
Color of Main Housing/Arms Light Gray/White
Air Intake Two side openings at base of unit
Air Outlet Via diffuser with horizontal 320 degree opening on top of unit

 